Flame Photometer FP8000 Series

Loại sản phẩm: Gas

Mã sản phẩm: Flame Photometer FP8000 Series

Nhà cung cấp: ANS Vietnam

Xuất Xứ: Chính hãng

Hãng sản xuất: Kruess

Giá : Vui lòng liên hệ

The A.KRÜSS flame photometers allow simple and cost-effective determination of alkali and alkaline earth element concentrations in aqueous solutions. They are mainly used in laboratory and process operations.

With the FP8000 series A.KRÜSS Optronic presents worldwide unique measuring devices for simultaneous measurement of the elements Na, K, Ca and Li. Five measurement channels are available to be individually configured. Thanks to the proven measurement procedure as well as to modern device electronics and innovative process control, our flame photometers achieve highly accurate and reproducible results. The devices can cope with about 300 measurements per hour and thus clearly demonstrate the international top position!

 

KEY FEATURES
  • Economic, robust and durable solution for use in laboratory and process operations
  • Maximum operational safety through intelligent security mechanisms
  • Flame photometry simultaneous measurement of up to five alkaline and alkaline earth elements
  • Fast measurement: up to 300 measurements per hour – international top position!
  • User administration with two authorisation levels
  • Traceability of all measured data and device-specific data
  • Complete traceability of measurement results
  • Extensive interfacing options and comfortable handover of measurement results
  • Compliance with international norms and standards such as GMP / GLP and 21 CFR Part 11

Solutions for various needs

  FP8400 FP8500 FP8600 FP8700
APPLICATIONS Standard version for
Laboratory

Economic entry solution
Version for Process

Remote control of
multiple devices via
centre process computer
Version with automated
sample feed
Version with automated
sample feed and dilution
  FP8400 FP8500 FP8600 FP8700
SAMPLER    
DILUTER      
MIXER      
VALVE BOX      

Equipment and Fields of Application

  FP8400 FP8500 FP8600 FP8700
DETERMINING
CONCENTRATION
Determining the concentrations of alkaline and alkaline earth elements in aqueous solutions for laboratory and process operations
Na, K, Ca, Li - Propane or acetylene
EQUIPMENT Basic device Basic device +

External valve box with control unit
(Online Measurement)
Basic device +

Sampler and external sample table and control unit
Basic device +

External automation system consisting of:
sampler, diluter and mixer
FIELDS OF
APPLICATION
Laboratory analysis

Quality control and evidence

Food laboratories

Examination offices

Chemical development
Process analysis

Process monitoring
Quality control and evidence

Food laboratories

Examination offices
Quality control and evidence

Food laboratories

Examination offices
  For operation with low sample throughput

Very high precision
Recommended for online measurements

Designed for automated continuous measurements
Automated procedures for operation with high sample throughput

Undiluted samples

Little support from users
needed

High precision
Automated procedures for operation with high sample throughput

Diluted samples

Little support from users needed

High precision

Small amount of sample

Easy handling and operating comfort

Our flame photometers are easy and intuitive to use on a large touchscreen display and with USB mouse.
The FP8000 series is designed for using propane or acetylene as fuel gas. Purified and dried compressed air is required for operation.
Aqueous samples, controls and standards can be measured manually or automatically. Calibration is carried out via the standards. Measurement results can be checked with the controls.
For reviewing, emission and concentration values of calibration are presented in graphed and tabulated order.

User administration

All devices feature a user administration with two authorisation levels, which can selectively be activated or deactivated.

Measurement principle of FP8000 Flame Photometers

The flame photometers of the FP8000 series apply a relative measurement method according to the principle of F-AES flame atomic emission spectroscopy.

Functionality of the FP8000 series

The FP-8000 devices come with five independent measurement channels and another, separate channel for monitoring the flame. The five measurement channels can be fitted with appropriate filters. The devices do not necessarily need a guideline, measurement can be done both with and without reference element.

Innovative Process Control

The flame photometers can be used as table top device or be integrated into a process environment via analogue current interface.
Several locally separated units can be controlled via one centre process computer. The units are designed for 24-hour operation.

High safety standard for maximum operational safety

Various safety mechanisms ensure particularly high operational safety. Such as a safety circuit for interrupting the supply of gas preventing leakage of unburned gases, or as a flame recoil blocker preventing the backward burning of an extinguished flame.

Documentation and compliance with global standards

The integrated data memory offers space for an unlimited number methods and up to 999 readings in a circular buffer. All measured values, system and method settings are recorded completely and without gaps. The documentation of the results is GMP/GLP-compliant and meets international norms and standards such as 21 CFR Part 11.

Interfaces and data export

Extensive interfaces offer a comfortable measuring value output. Firmware updates can easily be done via USB flash drive.

RS-232 USB ETHERNET
Serial ASCII printer USB flash drive
Barcode scanner
Keyboard
Mouse
Network printer
Network share
LIMS

Service and maintenance – Your benefits as an A.KRÜSS customer

  • On site services by A.KRÜSS Optronic or certified service partner:
    • Service
    • Maintenance
    • Initial installation and commissioning
    • DQ/IQ/OQ/PQ
    • Calibration and adjustment
  • Calibration and adjustment with defined standard solutions
  • Maintenance contracts, calibration certificates
  • Individual training and application consulting on site
  • Customer-specific customisation of devices (e. g. optimisation of measuring range)
  • Spare parts and accessories directly from the manufacturer

Features and specifications

  • High-precision measurement of the concentration of Na, K, Li and Ca in aqueous solutions
  • Flame photometry simultaneous measurement of up to five alkaline and alkaline earth elements
  • Fast measurement: up to 300 measurements per hour
  • User administration: optional setup, two authorisation levels can be activated or deactivated
  • Traceability of all measured data and device-specific data
  • Complete traceability of measurement results
  • Extensive interfacing options and comfortable handover of measurement results
  • Compliance with international norms and standards such as GMP / GLP and 21 CFR Part 11
  • TFT-Display with integrated touchscreen, 8,4″ (21 cm), 800×600 Pixel
  • Measurement principle: F-AES flame atomic emission spectroscopy

For prices and availability information on A.KRÜSS Flame Photometer, please contact your nearest Krüss distributor, who will be delighted to help.

PDFFor full technical specifications, please download the brochure here.

Sản phẩm liên quan

Cold Light Sources

Spectrometers

Spectroscopes

Thermostats

Software

Stereo Microscopes

Microscopes for Biology & ...

Microscopes

Melting Point Meters

Gas analysers of the MAT1 ...

Manual Polarimeter

Automatic Polarimeter

Automatic high-performanc ...

Density Meters

Manual Handheld Refractom ...

Process Refractometers

Abbe Refractometers

Digital Handheld Refracto ...

Digital Lab Refractometer ...